ELASTOROOF PU :  1K Polyurethane Waterproofing and Sealing Membrane

  • Slabs of RCC roofs, podiums, parking garages, bridge decks, water retaining structures, shopping malls etc.

ELASTOROOF 2K :  2K Polyurethane Waterproofing Membrane

  • Exposed RCC roofs, decks, slabs and podiums, swimming pools, water retaining structures etc.

SUNROOF PU :  Waterproofing and Sealing Membrane

  • Roofs, chajjas, parapet and exteral walls, sloping roofs etc.

SUNKOTE :  Single component, liquid applied, elastomeric, waterproof membrane

  • Waterproofing for all types of RCC surfaces such as roofs, chajjas, parapet walls, external walls, sunken areas, toilets etc.
  • Flat as well as sloping roofs
  • Conforms to IS 101, ASTM D 638, ASTM D 412, DIN 1048
  • Strong, thick, elastomeric, liquid applied waterproofing membrane system
  • UV Resistant
  • Single component and easily brush, roller or spray applied
  • Non-toxic in nature
  • Membrane allows concrete surface to breathe
  • Higher tensile strength, tear resistance & adhesion to substrate
  • Prime the surface using Sunprime at the rate of 8 -10 M2/Kg/coat. Apply 3 coats of SUNKOTE at the rate of 2.5-3.5 M2/Kg/coat with an interval of 6 - 8 hours between coats.

POLYKOTE 2C :  2K Cementitious, Elastomeric Waterproof Coating/Membrane

  • Flat or sloping roof slabs, chajjas, folded plate roofs, domes, sunken portion of bathrooms, toilets, balconies etc.

FLEXITOP POLYUREA :  Polyurea Coating/Membrane

  • Water tanks, swimming pools, ponds, pipelines, waste water treatments, industrial floors, roads, bridge decks etc.

FLEXITOP POLYUREA-H :  Hybrid Polyurea Coating/Membrane

  • Waterproof protective membrane for concrete and steel in a wide range of environmental conditions
  • Corrosion resistant as it provides a tough barrier against moisture,oxygen,and chlorides
  • Can be used in below grade waterproofing applications
  • General water isolation-water tanks,pools,swimming pools,ponds,pipes,pipelines,waste water treatments, manholes,and sewer linings,roof coatings
  • Floors-industrial floors,hospitals,factory,parking lots,garage
  • Waterproofing of bridge decks,railways,and high speed railway bridge decks,tunnels,airports
  • Suitable for the marine industry and marine applications
  • Suitable for high abrasion applications-oil and gas industry,refineries,petrochemical industry,mining, secondary containment,energy industry
  • Waterproofing in leisure industry-water parks,aquariums linings,playgrounds,theme park and decorative applications
  • Useful in applications of joint filling and sealing Roof waterproofing
  • Secondary containment
  • Excellent chemical resistance, thermal stability and UV resistance (some discoloration will occur)
  • Very fast turn-around time
  • Excellent impact,abrasion,and puncture resistance
  • Seamless and monolithic,including field joints
  • Significantly enhances the durability of reinforced concrete
  • Applicable even in the irregular surface
  • Low permeability values
  • Good anti-rooting properties
  • Can be applied at ambient temperatures from - 30°C to 70°C
  • Anti-root properties
  • Easy to apply
  • Excellent flexibility under low temperatures
  • All concrete surfaces should be clean, dry, and free from contamination.
  • Dry abrasive blasting, wet abrasive blasting,vacuum-assisted abrasive blasting, and centrifugal shot blasting may be used to remove contaminants, laitance, and weak concrete, to expose blowholes, and to produce a sound concrete surface with adequate profile and surface porosity. All blow holes and minor surface imperfections shall be filled with recommended filler prior to application of primer.
  • Surface must be bone dry with less than 4% moisture as checked with a digital moisture meter prior to application.
  • The surface has to be primed in order to achieve an even surface and good adhesion. A choice of primers is available depending on the type of substrate and weather condition.
  • Optionally, lightly spreading out with quartz sand over the tacky primer as required because this provides higher adhesion values and extends the maximum inter coat interval of primer prior to the application of the coating. In order to avoid the formation of blisters does not spread to excess.
  • Open FLEXITOP POLYUREA-H Part A and Part B container. Stir individual containers separately very well to get a homogeneous mixture.
  • Add Part A and Part B proportionally, as given in the technical datasheet, stir it well using a handheld low rpm (200 - 300) stirrer for about 2 - 3 minutes until the mixture becomes uniform.
  • Apply the mix as a base coat on the well primed surface using an airless spray gun, roller, or brush at the rate of 0.4 - 0.5 Kg/m 2. Apply 2 nd coat at same coverage after 4-6 hour interval. For higher thickness, additional coats may be applied. Surfaces with higher porosity may be primed with two coats of primer.

SUNDEKOTE MMA :  Methylmethacrylate Waterproof Membrane

  • Bridge decks, culverts, pedestrian and vehicular trafficked areas, stadium terracing, tunnels, dam structures, offshore platforms etc.